help-support-specification

Specifying Monarc

 Masterspec

 

Monarc Precast panels are fully supported through Masterspec's New Section 3130M Monarc Creative Precast Panels and Treads. 

Section 3130M is fully maintained up to date with the latest in New Zealand Standards & best industry practice. It also provides comprehensive guidance notes for both selecting and specifying the Monarc products helping you to communicate exactly what you want.

Section 3130m contains full Colour, Texture and Detail selection options making population of your specification document simple and quick.

You can access Monarc 3130M section through any Basic, Standard or landscape versions of the Masterspec Software or online with the New Masterspec Next Gen Software.

Or for non masterspec users Simply download the generic Masterspec Word document below and paste it directly into your specification document. 

 

 Masterspec Section 3130M - MONARC Creative precast panels and Treads. 

 

Or at any time please feel welcome to Contact us and a Monarc support person will be in contact.

help-support-downlaod

Downloads


 Monarc Creative Precast Product Brochure.PDF


 Masterspec Section 3130M 

MONARC Creative precast panels and Treads.  

 

 New Monarc Brochure

coming soon

  
   

  ***  This section is currently under development.  *** Please feel welcome to Contact Us and discuss any further requirements you may have. 

help-support-faq

Frequently Asked Questions

Q.1  What are the Maximum Dimensions for Monarc panels?

A.1  There are a number of parameters within which to design Monarc precast panels taking into consideration the physical ability of the Monarc processing machinery, crane and gantry capacities and Transportation constraints such as truck load limits, bridge heights and oversize special equipment etc...

The following 'safe' Monarc design parameters will assist you with economical design and provide a smooth transition from your Drawings to Panel installation.

  • 3.2 meters in either panel width or height
  • 350mm in panel thickness
  • Length subject to transport (Typically 12 meters)
  • Weight Max 20 tonne (overdimension panels require special review and considerations and may incur additional costs for special transportation, lifting and handling equipment .)
  • No projecting components or profiles. (substitute starter bars with threaded inserts)

Q.2  How Much Does Monarc Cost?

A.2  The price of Monarc is determined by your Monarc Product Selections and the time it will take to manufacture the Monarc panel. Monarcs offers a wide range of selections each providing variable Colours, Textures and decorative Detailing capabilities. Concrete Blends can vary significantly depending on the raw ingredients of Sand aggregates and cements types. Similarities in Monarc Panels allow us to pass on savings in production efficiencies to the project.

Please provide us with your Architectural and structural Drawings and we would be happy to provide an accurate quotation or budget estimate for you. 

Q.3 Can both faces of the panel be processed?

A.3 Yes, Monarc can provide some finishes double sided. Monarc can also provide hand honed edges to panels.

Please note that whilst we take all practical steps to deliver as close as possible matching finishes to both mould an near faces newtons law can prevail and Gravity can effect the visibility of aggregates at the top near face surface appearing less dense when compared to the mould face side of the panel, this is a natural uncontrollable occurrence in precast concrete production. 

Q.4 Can my Monarc panels be thermally insulated?

A.4 Yes Monarc panels can incorporate thermal insulation componentry into the precast panels

With a raft of experience in thermally insulated architectural panels Monarc Panels adopt a thicker front facing than typically recommended to accommodate the pneumatic pressures enduced onto the panel during Monarcs surface refinement processes. 

Typical panel widths increase form 250mm to 300mm and delvier R-values of  aprox R-2.5

 

Please don't hesitate to contact us, we would be happy to assist with any further questions you may have.

end faq

help-support-terms

Terms & Conditions

 

MONARC Creative Precast & Architectural Precast 

(As per Nauhria Precast - Standard Terms and Conditions)

*** IMPORTANT INFORMATION ***

 

9.0 MONARC™ & ARCHITECTURAL PRECAST

9.1 Expectation of precast panels finishes – Expectations over what constitutes an acceptable precast panel finish can often differ between the manufacturer (Nauhria), the contractor, the architect and the client. The following highlights inherent limitations in the production process that may help in narrowing the range of expectations between parties involved in the construction process. 

 

9.2 Appearance - With Monarc and all architectural precast, we take extreme care to ensure the product quality is the best that it can be. However concrete and its ingredients (sand, aggregate, cement, and oxides) are natural products and can have variations in colour, shape, size and natural properties. e.g. quartz crystal veins.

Concrete colour can also vary from day to day and panel to panel due to environmental fluctuations in temperature and humidity, raw material moisture content, concrete curing time, aggregate batching and source supply. With vibration of concrete it is also difficult to achieve a completely uniform distributed look.

With our development of Monarc Creative Precast we have established many effective procedures to reduce the inconsistencies and variances in concrete. We are, however, unable to guarantee that all panels will have precisely the same consistency and look.

 

9.3 Refinement - Monarc panels are manufactured within the limits and tolerances for precast panel manufacturing set out in NZS3109 1997.

During the Monarc manufacturing process, a thin layer of the cement surface is removed. Normally, and unless otherwise specified, panels are cast 5mm thicker than required to accommodate the removal of this cement layer.

With the removal process it is natural for concrete irregularities to become visible including air bubbles, cracks, and exposure of the concrete ingredients some of which can dislodged from the surface of the panel.

Nauhria accepts no liability for these irregularities made visible during the Monarc panel manufacturing process.

 

9.4 Chamfers / Edges - Monarc panels are typically manufactured with 15x15mm cast in chamfers.  The chamfer depth is reduced through Monarc processing to the face of the panel.

Unless specifically requested, Monarc processing of chamfers and panel edges is excluded i.e. units are provided with an unprocessed off the form finish.  By request chamfers and panel edges may be Monarc hand diamond honed, hand diamond brushed or hand bush hammered at an additional cost. Instruction to process chamfers & panel edges must be specifically requested at time of tender or specifically requested through the shop drawing process prior to manufacture.

If edges and/or chamfers are Monarc processed it is important for the client to understand that the process used on the edges and/or chamfers is not the same process that is used on the face of the panel, as such the edges and/or chamfers may look different to the panel face – depth of hand processing is generally less therefore revealing less aggregate surface and it is normal for air bubbles to be revealed on formwork side faces and panels edges among other possible differences.

Please note we are unable to offer MONARC edge finishes in window or door rebates.

 

9.5 Remedials – Further to item 7 above, Nauhria take all practical care to ensure damage to the panels is minimised. However, during the process precast panels go through - manufacture, storage, transportation, erections on-site and other construction movement on-site (drilling, diggers, scissor lifts etc), there is always a possibility that some damage could occur to the panels.

Nauhria have skilled people to carry out professional remedial work. However, very close inspection might reveal that remedial work has been undertaken.

 

9.6 Sealing / Coating - Aesthetic or functional reasons (matt, gloss, wet or natural look finishes or for graffiti protection) may require the need for the application of sealers and coatings.

Nauhria’s manufacturing environment is unsuited for the coating and sealing of precast panels and we, therefore, are unable to provide this product or service.

Please note that no allowance has been made for any type of sealers or coatings to be supplied or applied to these panels.

Nauhria recommend that panels be sealed or coated as soon as practically possible to reduce the occurrence of efflorescence, to protect against soiling, staining or graffiti and to add lustre, richness and shine to the panels.

A specialised trade in itself we recommend consulting with coating specialists such as Resene, Sika, Graffiti Solutions or other similar professional product and service providers.

 

9.7 Transportation, handling and erection of Monarc panels - Monarc panels are manufactured with approved cast-in lifting components. Nauhria take all practical care to avoid damage occurring to the panels during production, processing and pre delivery storage.

Nauhria accepts no liability for any damage caused as a result of the lifting, handling, securing, transportation, or erection of MONARC Panels from the moment of loading them on to delivery vehicles, trailers, flat racks, ‘A’ frames, and other means of transportation or storage apparatus.

We have made no allowance for extra protection during transportation.

 

9.8 Samples - Samples are made from actual concrete giving you the opportunity to touch, feel and see the richness and depth of the colour and are designed to provide an indication of colours and texture.  However Nauhria cannot guarantee that the final product will be exactly the same as the sample or consistently to the same standard.  Samples are unlikely to show the colour and texture variation experienced in larger areas and as stated above in 9.2 Appearances, concrete colour and texture can vary from day to day and panel to panel due to environmental fluctuations in temperature and humidity, raw material moisture content, concrete curing time, aggregate batching and source supply. With vibration of concrete it is also difficult to achieve a completely uniform distributed look.

 

9.9 General - MONARC™ and the Monarc logo are the registered trademark property of Nauhria Precast Limited. Unauthorised use of MONARC™ or the Monarc Logo is prohibited without authorized permission from the Managing Director or an appointed authorized employee of Nauhria Precast Limited.

For further information, or if you require clarification on any points relating to this document, please feel welcome to contact us at any time.

help-support-news



  • Monarc Wins Supreme Award (OCT 2013)


    The Hurstmere Green Takapuna Rejuvenation Project  received 3 awards including the Concrete 3 Sustainability Supreme Award at the 2013 Concrete conference held in Queenstown, New Zealand.

  • New 'Waterfall Matrix' Detail Design (Jan 2014)


    Monarc are pleased to present the new Monarc 'Waterfall Matrix' Detail design.

  • Best in Category (JUN 2014)


    Carlaw Park Student Accomodation Village received the Best in Category Award at the 2014 Property Council Awards. The project was designed by Warren & Mahonney Architects and was built by Haydn & Rollett Construction and demonstrates excellence in both the design and construction.

Specifications and technical information

Reveiw technical data and gain understanding about Monarc, Download CAD drawings or select the new Masterspec section 3130M for inclusion into your project.

Best in Category (JUN 2014)


Carlaw Park Student Accomodation Village received the Best in Category Award at the 2014 Property Council Awards. The project was designed by Warren & Mahonney Architects and was built by Haydn & Rollett Construction and demonstrates excellence in both the design and construction.

Read more...